Fire Alarm System

  • 0 out of 5

    12 ZONE FIRE ALARM PANEL

    FP 12 Zone Conventional Fire Alarm Panel (expandable to 14 zones)

     FF392-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • 12 conventional Zone circuits (expandable to 14).
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 7Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
  • 0 out of 5

    2 ZONE FIRE ALARM PANEL

    FP 2 Zone Conventional Fire Alarm Panel

     FF382-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • Two conventional Zone circuits.
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters and other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 2.3Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).

    A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
    Optional repeaters and relay expansion boards are also available

  • 0 out of 5

    4 ZONE FIRE ALARM PANEL

    CFP Standard 4 Zone Conventional Fire Alarm Panel

     CFP704-4

    LPCB certified to EN54-2/4, C-TEC’s CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

    Supplied in an attractive flush or surface mountable plastic enclosure, it includes four detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

    A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

    Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.

  • 0 out of 5

    8 ZONE FIRE ALARM PANEL

    FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones)

     FF388-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • Eight conventional Zone circuits (expandable to 14).
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 7Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations)
  • 0 out of 5

    CONVENTIONAL SOUNDER

    CONVENTIONAL OPEN-AREA SOUNDER – RED BODY

    The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation.

    • For use with conventional systems
    • A choice of 32 tones including all the major international standards
    • Simple ‘First Fix’ installation
    • Volume control – typical 8dB
  • 0 out of 5

    Fire Alarm Cable Beldon U.SA

    Fire Alarm Cable Beldon U.SA

     

  • 0 out of 5

    Fire Alarm Panel (1-2) Addressable Firex UK

    Fire Alarm Panel (1-2) Addressable Firex UK

    Features and Benefits
    • Listed to LPCB standard
    • 2 Loop capacity-477 Addressable Point
    • 8×18 Graphical LCD Display
    • 30 Zone indication including manual intervention and control
    • 3 programmable alarm output
    • Positive Alarm Signal (PAS) Pre-alarm
    • Maintenance report of dirty detector
    • Networkable with all FX Intelligent Fire Alarm panels
    • Programmable form PC by FX Def2.1
    • History log 999-events capacity in non-volatile memory
    • Test Facility-Silent Mode
    • Device Start/Stop Mode
    • Device Enable/Disable
    • RS485 Repeater Output (Max. 10)
    • Advanced user friendly programming software including ‘Fuzzy Logic’
    • Optional RS 232 Color Graphics Software, Printer and Pager Interface
    • Optional RS485 Network Card
    • Optional Panel Printer

  • 0 out of 5

    FIRE ALARM PANEL (12 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 2 Zone Conventional Fire Alarm Pane

    The conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price. The panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting.
    Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 2 Zone

    The FX104 conventional fire control panels provide two zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors. Operation of the panel are very simple. All control functions are realized through a key switch.

    Microprocessor controlled SMT Electronics
    The FX 104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing. Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch. The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.

     

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 2 Zone

    Product Description

    The FX108 conventional fire control panels provide eight zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors.

    Microprocessor controlled SMT Electronics
    The FX108 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing.
    Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch.
    The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 2 Zone Conventional Fire Alarm Panel

    The conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price. The Xenex panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting.
    Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

  • 0 out of 5

    FIRE ALARM PANEL (4 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 4 Zone

    The FX104 conventional fire control panels provide four zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors. Operation of the panel are very simple. All control functions are realized through a key switch.

    Microprocessor controlled SMT Electronics
    The FX 104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing. Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch. The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.