- Read moreQuick View
12 ZONE FIRE ALARM PANEL
FP 12 Zone Conventional Fire Alarm Panel (expandable to 14 zones)
FF392-2
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 12 conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Read moreQuick View - Read moreQuick View
2 ZONE FIRE ALARM PANEL
FP 2 Zone Conventional Fire Alarm Panel
FF382-2
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Two conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters and other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards are also availableRead moreQuick View - Read moreQuick View
4 ZONE FIRE ALARM PANEL
CFP Standard 4 Zone Conventional Fire Alarm Panel
CFP704-4
LPCB certified to EN54-2/4, C-TEC’s CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes four detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.
Read moreQuick View - Read moreQuick View
8 ZONE FIRE ALARM PANEL
FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones)
FF388-2
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Eight conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations)
Read moreQuick View - Read moreQuick View
CONVENTIONAL SOUNDER
CONVENTIONAL OPEN-AREA SOUNDER – RED BODY
The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation.
- For use with conventional systems
- A choice of 32 tones including all the major international standards
- Simple ‘First Fix’ installation
- Volume control – typical 8dB
Read moreQuick View - Read moreQuick View
Fire Alarm Panel (1-2) Addressable Firex UK
Fire Alarm Panel (1-2) Addressable Firex UK
Features and Benefits
• Listed to LPCB standard
• 2 Loop capacity-477 Addressable Point
• 8×18 Graphical LCD Display
• 30 Zone indication including manual intervention and control
• 3 programmable alarm output
• Positive Alarm Signal (PAS) Pre-alarm
• Maintenance report of dirty detector
• Networkable with all FX Intelligent Fire Alarm panels
• Programmable form PC by FX Def2.1
• History log 999-events capacity in non-volatile memory
• Test Facility-Silent Mode
• Device Start/Stop Mode
• Device Enable/Disable
• RS485 Repeater Output (Max. 10)
• Advanced user friendly programming software including ‘Fuzzy Logic’
• Optional RS 232 Color Graphics Software, Printer and Pager Interface
• Optional RS485 Network Card
• Optional Panel PrinterRead moreQuick View - Read moreQuick View
Fire Alarm Panel 8 Addressable Firex UK
Fire Alarm Panel 8 Addressable Firex UK
Features and Benefits
- Listed to LPCB
- 8 x Loops (242) capacity (1936) addressable points
- Maximum 10 Loops Standalone
- Modular constructed for future expansion
- 40 x15 lines Colour Graphical LCD Display
- Up to 999 programmable zones and 140 zone indication
- Auto Programming Day and Night Mode
- Enable and Disable function
- PAS and Acknowledge Function
- Dirty Detector Reporting
- Duplicate Address Checking
- Walk Test Function with optional silent mode
- Can edit device detailed and programmed
- Programmable from PC or Panel
- History record-999 fire incident only and 999 event capacity in non-volatile memory Fully simulation of Cause and Effect
- Advanced user friendly programming software including ‘Fuzzy Logic’
- Networked with all FX Intelligent Fire panels up to 64 panels, Optional CAN BUS, Fiber Optic and LAN Network Interface
- RS 485 mimic and repeater output up 64
- RS 232-USB CRT interface, including FX GMC graphic, Epson commercial printer, and BMS
- Built in Fire Alarm, FPE, Fault and Alarm Router output
- 80 column Panel Printer included
- Built in Battery charger
Read moreQuick View - Read moreQuick View
Fire Alarm Panel China brand Addressable
Fire Alarm Panel China brand Addressable
The analogue addressable control and indicating equipment forms the central part of a fire detection and alarm system. The fully networkable 2-wire 6000 is compatible with Numens addressable devices and can also be connected to non-addressable devices when used with addressable input modules.
Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile cause-and-effect PC-based programming tool enables rapid customization with software for sites that require special operating features.
The 6000 comes standard with features that allows flexibility and expandability.Features:
·Single loop or 2-loop options available
·Networkable,up to 4 control panels
·Up to 125 addressable devices
·Automatic device detection on start-up
·Automatic device type-code verification
·2 independently programmable non-addressable A/V alarm output circuits
·2 programmable Fire Alarm relay outputs
·Fault relay output
·Backlit LCD display providing 4 rows of 40 characters
·16 zone fire alarm LED indicators
·3000 event history logRead moreQuick View - Read moreQuick View
Heat Detector
Heat Detector (84 to 100°C)
The Context Plus Conventional Series 65E Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. Wide-operating voltage of 9–33VDC. Wide-operating and storage temperature of -20°C to +60°C. Can be used on security systems. Proven detection performance. Can be used for applications where smoke detectors are unsuitable. Ideal for environments that are dirty or smoky under natural conditions. Wide operating voltage. Flashing LED.
Read moreQuick View - Read moreQuick View
Heat Detector Addressable Firex UK
Heat Detector Addressable Firex UK
Features and Benefits
Dual fixed temperature heat detector that combines both fixed temperature and rate of rise heat detection in a single sensor. As standard, the fixed temperature is set to 58ºC while the rate of rise is set to 3ºC in one minute.
Built in 8 bit microprocessor
Analogue sensing
Secure and speedy communication
Self-diagnosis and history log
Field programmable electronically addressed
Twin LED for 360º vision
Low profile design
Built-in remote indicatorRead moreQuick View - Read moreQuick View
Heat Detector China brand Addressable
Heat Detector China brand Addressable
Read moreQuick View - Read moreQuick View
Heat Detector Gent By Honeywell Addressable
Heat Detector Gent By Honeywell Addressable
The S4-710 is specifically designed to be used with the Gent Vigilon range of Analogue Addressable Control Panels. This detector is an Optical Type Analogue Addressable Smoke Detector combined with a Heat Detection Element. It requires a Gent S4-700 base for mounting.
The S4-710 is a truly intelligent analogue sensor combining local processing in the sensor and the panel to achieve an immediate response to real fires whilst minimising the risk of false alarms.
Read moreQuick View