• 0 out of 5

    12 ZONE FIRE ALARM PANEL

    FP 12 Zone Conventional Fire Alarm Panel (expandable to 14 zones)

     FF392-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • 12 conventional Zone circuits (expandable to 14).
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 7Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
  • 0 out of 5

    2 ZONE FIRE ALARM PANEL

    FP 2 Zone Conventional Fire Alarm Panel

     FF382-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • Two conventional Zone circuits.
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters and other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 2.3Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).

    A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
    Optional repeaters and relay expansion boards are also available

  • 0 out of 5

    4 ZONE FIRE ALARM PANEL

    CFP Standard 4 Zone Conventional Fire Alarm Panel

     CFP704-4

    LPCB certified to EN54-2/4, C-TEC’s CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

    Supplied in an attractive flush or surface mountable plastic enclosure, it includes four detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

    A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

    Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.

  • 0 out of 5

    8 ZONE FIRE ALARM PANEL

    FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones)

     FF388-2

    • Installer-friendly design.
    • Robust metal enclosure c/w lift off lid & heavy-duty base connections.
    • Eight conventional Zone circuits (expandable to 14).
    • Two conventional Sounder circuits.
    • Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
    • Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
    • Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
    • Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
    • Multi-lingual variants (subject to quantities).
    • Space for 2 x 12V 7Ah VRLA batteries.
    • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
    • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations)
  • 0 out of 5

    CONVENTIONAL SOUNDER

    CONVENTIONAL OPEN-AREA SOUNDER – RED BODY

    The Conventional Open-Area Sounder is a conventional sounder which makes use of the TimeSaver Base resulting in a faster and more reliable installation.

    • For use with conventional systems
    • A choice of 32 tones including all the major international standards
    • Simple ‘First Fix’ installation
    • Volume control – typical 8dB
  • 0 out of 5

    Heat Detector

    Heat Detector  (84 to 100°C)

    The Context Plus Conventional Series 65E Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. Wide-operating voltage of 9–33VDC. Wide-operating and storage temperature of -20°C to +60°C. Can be used on security systems. Proven detection performance. Can be used for applications where smoke detectors are unsuitable. Ideal for environments that are dirty or smoky under natural conditions. Wide operating voltage. Flashing LED.

  • 0 out of 5

    MANUAL CALL POINT (MCU)

    CONVENTIONAL I.S. MANUAL CALL POINT – OUTDOOR (WITHOUT LED)

    The Manual Call Point is used to manually initiate an alarm signal on the fire detection system. The Manual Call Point is suitable for use in areas where explosive atmospheres are, or may be, present.

    • Suitable for intrinsically safe and weatherproof applications
    • Suitable for use on Zones 2, 1 & 0
    • EN 54-11 Certified
  • 0 out of 5

    SMOKE DETECTOR

    Series 65E Optical Smoke Detector With Flashing Led

    The Context Plus Conventional Series 65E Optical Smoke Detector incorporates an optical chamber that houses an infrared light emitting diode (LED) and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Wide-operating voltage of 9–33VDC. Wide-operating and storage temperature of -20°C to +60°C. Can be used on security systems. Proven detection performance. It has an indicator LED which is clear in quiescent state but produces a red light in alarm. Responds well to slow-burning, smouldering fires. Well-suited to bedrooms and escape routes. Unaffected by wind or atmospheric pressure. Flashing LED.