Conventional Fire Alarm System

  • 0 out of 5

    FIRE ALARM PANEL (12 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 2 Zone Conventional Fire Alarm Pane

    The conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price. The panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting.
    Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 2 Zone

    The FX104 conventional fire control panels provide two zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors. Operation of the panel are very simple. All control functions are realized through a key switch.

    Microprocessor controlled SMT Electronics
    The FX 104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing. Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch. The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.

     

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 2 Zone

    Product Description

    The FX108 conventional fire control panels provide eight zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors.

    Microprocessor controlled SMT Electronics
    The FX108 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing.
    Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch.
    The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.

  • 0 out of 5

    FIRE ALARM PANEL (2 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 2 Zone Conventional Fire Alarm Panel

    The conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price. The Xenex panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting.
    Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

  • 0 out of 5

    FIRE ALARM PANEL (4 ZONE) FIREX UK CONVENTIONAL

    Conventional Firex UK Fire Alarm Panel 4 Zone

    The FX104 conventional fire control panels provide four zones of fire detection. These panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988 and EN 54 parts 2 and 4. Each zone can be connected with 15 conventional fire detectors. Operation of the panel are very simple. All control functions are realized through a key switch.

    Microprocessor controlled SMT Electronics
    The FX 104 conventional control panels are multi-wire fire alarm developed from SCM. Those with signal output interface board has a passive normally open alarm output contacts and fault output contact on each zone. They have two external control output points to control some devices such as sounder, sounder strobe or bells. Designed with internal standby battery connection and housing. Multiple functions like isolation and test, setting day/night mode, indication of normal state, fault state, alarm state, short and open circuit alarm and identifying the location of detector zone. All control function is realized through a key switch and programming function realized through a key switch and a DIP switch. The FX conventional panels includes an advanced range of facilities which make this the Ideal panel for both standalone solutions, or integrated to larger systems in applications such as, shopping Centers and industrial complexes.

  • 0 out of 5

    FIRE ALARM PANEL (4 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 4 Zone Conventional Fire Alarm Pane

    The conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price. The  panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting.
    Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

  • 0 out of 5

    FIRE ALARM PANEL (8 ZONE) HONEYWELL GENT CONVENTIONAL

    Honeywell Gent 8 Zone Conventional Fire Alarm Panel

    The Gent  fire alarm panel is a highly cost effective conventional option for building premises requiring coverage to eight zones. Certified to Parts 2 & 4, the panel contains integral power supply and battery standby capacity for up to 72hrs.
    With eight alarm sounder circuits, repeat panel output, remote evacuation control and one-man test and commissioning, by Gent is a leader in conventional panel technology.

  • 0 out of 5

    Fire Alarm Panel 1 Loop Apollo Uk Addressable

    Addressable Apollo UK Fire Alarm Panel 1 Loop

    C-TEC’s XFP single loop 16 zone addressable fire alarm panel offers high performance at a very competitive price.

    LPCB certified to EN54 parts 2 & 4, it is supplied in an attractive flush or surface mountable plastic enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo’s XP95/Discovery protocol.

    Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe’s best-selling entry-level addressable fire panels.

    Packed full of engineering features – some of which are not available on more expensive alternatives (see feature list below) – the XFP501E/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.

  • 0 out of 5

    Fire Alarm Panel 2 Loop Apollo Uk Addressable

    Addressable Apollo UK Fire Alarm Panel 2 Loop

    C-TEC’s XFP two loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.

    LPCB certified to EN54 parts 2 & 4, it is supplied in durable metal enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo’s XP95/Discovery protocol.

    Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe’s best-selling addressable fire panels.

    Packed full of engineering features – please refer to the feature list below – the XFP502/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable

  • 0 out of 5

    FIRE CLASS ITALY J408-2 (2 ZONE) CONVENTIONAL FIRE PANEL

    Fireclass J408-2 2 Zone Conventional Fire Panel

    Designed and made according to EN54 standards, the J408 is a microprocessor based control panel for small to medium applications. It has 8 zones, each supports up to 32 detectors, for a maximum of 256 detectors. Each detection zone has an alarm-repeat output for selective management in the event of fire.

    The control panel has supervised, silence able alarm-outputs for self-powered sirens, piezo electric sirens, fire bells, flashers, telephone diallers, etc. This easy-to-use control panel is protected by a lockable front plate which allows operational access to authorized personnel only. The optional Software in Windows™ environment, allows full systems management of events memory, files, reset and all the programmable functions provided by the control panel.

  • 0 out of 5

    FIRE CLASS ITALY J408-4 (4 ZONE) CONVENTIONAL FIRE PANEL

    FIRECLASS J408-4 CONVENTIONAL FIRE ALARM CONTROL PANEL – 4 ZONE

    The FireClass J408-4 is a 4 zone conventional fire alarm control panel.

    Designed and made according to EN54 standards, the J408 is a microprocessor based control panel for small to medium applications. Each detection zone has an alarm-repeat output for selective management in the event of fire. The control panel has supervised, silenceable alarm-outputs for self-powered sirens, piezoelectric sirens, fire bells, flashers, telephone dialers,etc.

    This easy-to-use control panel is protected by a lockable frontplate which allows operational access to authorized personnel only.

  • 0 out of 5

    HEAT DETECTOR